A terminal has to echo the line the user just typed, and that length is a cell, not a constant; clb_puts cannot do it because .tp takes a literal address. So this one walks MAX compile time slots and decides per slot whether to print: CNT starts as a copy of LEN, clb_nonzero turns "CNT != 0" into the flag F, and the print happens inside `biz F` with the countdown *inside* the guarded body as well. That last detail is the whole bug this round: with clb_dec_ip outside the guard, a CNT of 0 wrapped to 2047 on the first skipped cell and the rest of the buffer came out (LEN=0 printed E F G H). The fix is also why the driver covers LEN = 3, 0 and 8 -- the zero case is what caught it. drv/puts_dyn.r8asm 13376 chars, out 65 66 67 65 66 67 68 69 70 71 72 (ABC, nothing, ABCDEFGH) reference machine "ABCABCDEFGH" 6306 steps Also learnt: `copy` takes two arguments (%this is the source), and it wants a clean buffer -- the first version passed three and then reused a dirty T, which showed up as a countdown that started from the wrong value. Not in asm/test.r8asm: an 8 slot version costs thousands of characters and the flagship is about a thousand under the 65536 limit. SPEC 5.3 records the contract and that exception; the macro count is 53.
22 lines
379 B
Plaintext
22 lines
379 B
Plaintext
%include "asm/puts_dyn.r8asm"
|
|
|
|
; raw_puts_dyn 单点验证:MSG 八格放 A..H,分别按 LEN = 3 / 0 / 8 打。
|
|
; out 65 66 67 65 66 67 68 69 70 71 72
|
|
.var MSG 10
|
|
.var LEN 20
|
|
.var CNT 21
|
|
.var F 22
|
|
.var T 23
|
|
|
|
%for k 8
|
|
load MSG+k 65+k
|
|
%endfor
|
|
|
|
load LEN 3
|
|
raw_puts_dyn MSG 8 LEN CNT F T
|
|
load LEN 0
|
|
raw_puts_dyn MSG 8 LEN CNT F T
|
|
load LEN 8
|
|
raw_puts_dyn MSG 8 LEN CNT F T
|
|
|