The data ring is part of the ISA and cannot go away (64 addressable cells, one 6116
or 512 flip flops), but the program RAM and the loader are not part of the
machine: copying the tape into RAM would put another machine inside this one and
lose the premise that the tape is the program. So the default architecture is now
execute in place: ip is the address of the tape memory, the fetched byte yields
three bits of opcode, and the bracket scans are address increments and decrements.
That works with a parallel EEPROM or flash (28C256, 29C010, 39SF010): fifteen
address lines, eight data lines, no glue logic, and the chip in a socket is the
cartridge. On an FPGA the tape is block RAM initialised from the bitstream, which
also needs no loading step and no external chip. LOAD then RUN stays in the
document only as an optional peripheral for media that cannot be addressed:
mechanical tape, serial SPI flash, floppy.
One consequence is now stated as a requirement rather than an option: with in
place execution a bracket scan costs a clock per instruction, and the calculator
main loop wraps almost the whole 51378 instruction tape, so a scanning ] would
cost 51 k clocks per round -- 51 ms at 1 MHz, paid on every character read. The
loop stack implementation (pop on ], no rescan) is therefore the default, and it
is also what makes mechanical media viable at all.
The packer output is correspondingly simpler: the .bin is literally the memory
contents, ready for a programmer or a block RAM init file. No image layout, no
FAT, no loader to write.